Open/close spindle tool clamp | |
Open/close tool rack cover | |
Extend/retract touch probe |
M10 | Clamp tool in spindle |
M11 | Unclamp tool in spindle |
M21 | Pick up new tool (used by M6 procedure) |
M22 | Put away current tool (used by M6 procedure) |
M23 | Measure and verify current tool (used by M6 procedure) |
M24 | Remeasure and store Z Reference in Parameter 942 |
M40 | Extend touch probe |
M41 | Retract touch probe |
M46 | Open tool rack cover (used by M6 procedure) |
M47 | Close tool rack cover (used by M6 procedure) |
M61 | Probe center of die, set part zero there |
Parameter | Typical value | Meaning |
---|---|---|
940 | 1.675 | X spacing between touch probe centerline and spindle centerline |
941 | 0.010 | Error tolerance for subsequent measurements of same tool |
942 | -6.076 | Z Reference for tool measurement (distance down from home to trip touch probe on tool pad) |
943 | 0.000 | Y spacing between touch probe centerline and spindle centerline |
950 | -1.500 | Y axis spacing between tool rack pockets |
951 | -6.860 | Z position (in WCS #6) where spindle just clears tool holders in rack |
952 | -7.790 | Z position (in WCS #6) to pick up and drop off tool holders in rack |
Variable | Typical value | Meaning |
---|---|---|
159 | 0 - 7 | Tool number currently in spindle |
Location | Use |
---|---|
WCS #1 - #5 (G54-G58) |
Available for machining parts |
WCS #6 (G59) |
Reserved for tool rack location: X0Y0 at Tool 1 pocket, Z0 at machine home |
Return Point #3 (G30 P3) |
Touch probe aligned over tool touch pad |
Return Point #4 (G30 P4) |
Spindle aligned over tool touch pad (tool-measuring start point) |
The PLC program can generate the following error and fault messages, in addition to those listed in the Centroid operator's manual:
You attempted to start the spindle, but the tool clamp is open.
Close the clamp, or load a tool as needed with M6, then try again.